Welcome to V.K.Scientific Instruments
TimeWe'are open : Mon - Sat 9:00 - 18:00

Have a question ?

+918882774870 08071280220
Vicat Needle Apparatus

Vicat Needle Apparatus

1500 INR/Set

Product Details:

  • Display Type Graduated scale (Mechanical)
  • Temperature Room temperature (typically 25C)
  • Humidity Ambient
  • Port Size --
  • Test Range Initial to final setting time of cement/plaster
  • Resolution 1 mm graduation
  • Equipment Type Vicat Needle Apparatus
  • Click to view more
X

Vicat Needle Apparatus Price And Quantity

  • 1 Set
  • 1500 INR/Set

Vicat Needle Apparatus Product Specifications

  • Vicat Needle Apparatus
  • Determines setting time and consistency of cement and other materials
  • 0-50 mm penetration
  • Approximately 4 kg
  • Manual operation
  • Standard Vicat needle: 300 g plunger
  • 1 mm
  • Immediate (manual observation)
  • Manual
  • --
  • Bench/Table Top
  • 250 mm (approximate device height)
  • Single specimen at a time
  • Laboratory testing of cement/plaster
  • --
  • Ambient
  • Room temperature (typically 25C)
  • Not Required (Manual apparatus)
  • Initial to final setting time of cement/plaster
  • Manual
  • Graduated scale (Mechanical)
  • 1 mm graduation
  • Movable rod with needle attachments, graduated scale, Vicat mould, base plate, weights
  • --
  • --
  • 70 mm diameter 40 mm height mould (approx.)
  • 300 g (standard) or as per IS:4031/ASTM C187
  • 1 mm diameter, 50 mm long
  • Non-porous, polished
  • Brass and stainless steel
  • 1 mm

Vicat Needle Apparatus Trade Information

  • Cash in Advance (CID)
  • 10 Set Per Month
  • 5-7 Days
  • All India

Product Description

IS 4031, 2645, 2542 (PART-1), 1727, 5513 & 712 BS 12, 146, 915, 1370, 4027, 4246, 4248 AASHTOT 129,E131 This instrument is used for determining the normal consistency and setting times of cement and 'A' class limes.


Specification: The apparatus consists of a metallic frame bearing a freely movable and with a cap at top, one vicat mould and glass base plate and one set of needles one each initial needle, final needle and consistency plunger.



Precision and Simplicity in Testing

Engineered for accuracy, the Vicat Needle Apparatus offers a straightforward method to assess the setting characteristics of cement and plaster. Its mechanical operation and graduated scale deliver immediate, reliable measurements with a resolution of 1 mm. The manual control allows users to observe and record results without external power sources or electronic interference.


Durability and Compliance

Constructed from quality brass and stainless steel, the apparatus promises longevity while maintaining industry standards such as IS:4031 and ASTM C187. The non-porous, polished base plate and stable bench-top mounting maximize repeatability and mitigate error, catering to routine laboratory assessments across India.

FAQ's of Vicat Needle Apparatus:


Q: How is the Vicat Needle Apparatus used in cement testing?

A: The Vicat Needle Apparatus is employed to determine the setting time and consistency of cement or plaster. The sample is placed in the Vicat mould, and the needle is gently lowered manually to record penetration depth via the graduated scale. Measurements indicate initial and final setting times as the material hardens.

Q: What materials are compatible with the Vicat Needle Apparatus?

A: This apparatus is suitable for testing cement, plaster, and other similar construction materials requiring assessment of setting time and consistency, following IS:4031 or ASTM C187 standards.

Q: When should I use the Vicat Needle Apparatus during laboratory procedures?

A: The apparatus should be used immediately after mixing the cement or plaster, in accordance with standard test protocols, to monitor the hardening process from initial to final setting time under ambient laboratory conditions.

Q: Where is the Vicat Needle Apparatus typically installed?

A: It is designed for bench or table-top mounting, making it ideal for use in educational, research, and quality control laboratories involved in materials testing.

Q: What are the steps involved in conducting a standard Vicat needle test?

A: A test begins with filling the mould with the sample, leveling its surface, and lowering the needle to the surface. The operator then releases the plunger and notes the penetration depth at set time intervals, repeating the process until setting criteria are met.

Q: Which benefits does manual operation offer compared to electronic alternatives?

A: Manual operation ensures immediate observation and greater user control, removing the dependency on a power supply. It also simplifies maintenance and is cost-effective for routine laboratory testing.

Q: How does the apparatus ensure test accuracy?

A: Its mechanical graduated scale, clearly defined 1 mm graduations, and rigid construction allow precise measurement of penetration depth, resulting in consistent and reliable results with every test.